| Properties | Product Data | Test Method | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Standard Electrical Insulating Rubber | General Purpose Electrical Insulating Rubber | Common Electrical Insulating Rubber | |||||||||
| NE-T-1 | NE-T-2 | NE-C-1 | NE-C-2 | NE-D-1 | NE-D-2 | NE-E-1 | NE-E-2 | ||||
| NE-T-1U | NE-T-2U | NE-C-1U | NE-C-2U | NE-D-1U | NE-D-2U | NE-E-1U | NE-E-2U | ||||
| Appearance | Product inherent color, no extraneous matter. | Visual Inspection | |||||||||
| Density, g/cm3 | 1.48~1.56 | ASTM D792 | |||||||||
| Hardness, Shore A | 62±4 | 60±4 | ASTM D2240 | ||||||||
| Tensile Strength, MPa ≥ | 4.5 | 4.0 | ASTM D412 | ||||||||
| Elongation at Break, % ≥ | 260 | 280 | 260 | 280 | 220 | 240 | 220 | 240 | |||
| Tension Set, % ≤ | 2.0 | ||||||||||
| Tear Strength, Die C kN/m ≥ | 13.0 | 12.0 | ASTM D624 | ||||||||
| Volume Resistivity, Ω▪ cm ≥ | 7×10 14 | 5×10 14 | 3×10 14 | 1×10 14 | IEC 60093 | ||||||
| Dielectric Strength, kV/mm ≥ | 22 | 20 | 18 | IEC 60243 | |||||||
| Dielectric Loss , tg δ ≤ | 3×10 -2 | 6×10 -2 | 7×10 -2 | IEC 60250 | |||||||
| Dielectric Constant | 3~4 | ||||||||||
| Tracking Resistance &Erosion resistance | 1A4.5 grade | pass | IEC 60587 | ||||||||
| Erosion Depth, mm ≤ | 2.5 | ||||||||||
| Flame Retardancy, 3mm | FV-0 | IEC 60695-11-10 |